Classic Flame 36EB110-GRT Manual de Instruções Página 10

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 47
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 9
Figure 9
E-9
CONTROL
SECTION 6: 208/240V WIRING INSTRUCTIONS
1.) Loosen the screw securing the junction box cover and remove the cover.
2.) Pull the power supply wires through the hole in the cover.
3.) Pull out the 5 wires marked L1, L2, N, G, S from the junction box on the side of the
builder box.
4.) Connect the black L1 wire and red L2 from the unit to the two dedicated 15 amp
lines from the power supply.
5.) Connect the white N wire from the unit to the white N from power supply.
6.) Connect the green ground G wire from the unit to the ground from the power supply.
7.) Plug the S wire connector into the provided sign wire.
8.) Ensure that all connections are tight.
9.) Secure all the wiring with wire-caps, then insert into the junction box.
10.) Remount the junction box cover (see figure 8 & 9.)
Note: 36EB220-GRT & 36EB221-GRC will only work with a two phase 208/240v
power supply. Single phase 208/240v is not supported and will void the warranty.
208/240 V
Configration
L2 White W/Red Stripe
L2 White W/Red Stripe
White W/Red
Min. 14AWG WIRE
FROM POWER SUPPLY
(NOT SUPPLIED)
Min. 14AWG WIRE
FROM POWER SUPPLY
(NOT SUPPLIED)
Vista de página 9